category: hazardous waste sites

National Priorities List Sites: Minnesota

Minnesota. BOISE CASCADEY ONAN CORP.Y MEDTRONICS INC . MINNESOTA EPA ID ... Onan Corporation acquired 133 acres of the Boise Cascade property , and ... 4,000 feet of the site . Several residences are located within 500 feet of ...

Handbook: Remedial Action at Waste Disposal Sites

... ( ASTM D2166 ) , triaxial compres- sion tests ( D2850 ) , direct shear tests ( ASTM D3080 ) , and grain size analyses ( ASTM D421 , D422 , and D1140 ) . The foundation material should be spread over the wastes in 6 - inch lifts and ...

SITE Program Demonstration Test: Terra Vac in Situ Vacuum Extraction System, Groveland, Massachusetts

... diagram of equipment layout 8 • 3.2 Schematic diagram of an extraction well 9 3.3 Soil formations 10 • 3.4 Soil ... Wellhead TCE concentration vs time : EW1S . . 66 • 67 73 6.5 6.6 Wellhead TCE concentration vs time : EW1D . Wellhead TCE ...

Proposals Regarding Superfund and Related Tax Provisions: Hearing Before the Committee on Ways and Means, House of Representatives, Ninety-ninth Congress, First Session, May 9, 1985

... ( NCP ) revisions , uti- lizes a flexible , site - by - site approach in determining the extent of cleanup , while at the same time making existing environmental stan- dards a factor to be considered when determining site cleanup . AMC ...

Critical Issues in Water and Wastewater Treatment: Proceedings of the 1994 National Conference on Environmental Engineering, Boulder, Colorado, July 11-13, 1994

... problem . The first intent of this study is to describe the national occurrence of bromide ion in drinking water ... ( IC ) using a Dionex ( DX300 ) IC with an IonPac AS9 column with a minimum detection limit of 5 μg / l . Bromate was ...

Requirements for Hazardous Waste Landfill Design, Construction, and Closure

... D624 Modulus of elasticity Hardness ΝΑ NA ASTM D2240 Duro A or D ASTM D2240 Duro A or D Duro A or D Puncture resistance FTMS 101B , Method 2065 ... ASTM D1204 ASTM D1204 Property Air - oven aging Water vapor transmission Water absorption 32.

Management of Investigation-derived Wastes During Site Inspections

... response , EPA wishes to clarify the discussion in the preamble to the proposed NCP . CERCLA section 101 ( 23 ) defines " removal " to include ... water diversions and air or surface water releases . Commenters asserted ... 14 15 222 31 31 31.

National Conference on Management of Uncontrolled Hazardous Waste Sites

... 6. As above , but hazardous gases / vapors result 7. Liquids or solids that ... combustion / reaction products Highly toxic combustion / reaction products ... worksheet of Figure 3. There are six additive vulnerability parameters , with a ...

Management of Uncontrolled Hazardous Waste Sites

... 6. As above , but hazardous gases / vapors result 7. Liquids or solids that ... combustion / reaction products Highly toxic combustion / reaction products ... worksheet of Figure 3. There are six additive vulnerability parameters , with a ...

Private Cost Recovery Actions Under CERCLA

... ( c ) ( 3 ) ( ii ) , in subpart H of the NCP , states that " [ a ] ny response ... ( c ) ( 3 ) ( ii ) sets forth a reasonable ap- proach to interpreting and ... section 106/122 orders or decrees , those documents implement remedies that ...

Hazardous Waste and Real Property Transactions: Program Material, April/May 1986

... outline necessarily is only a snapshot of some of the legal considerations as they appear as of the date this outline was prepared . The reader should be alert to the possibility that ... Outline: Hazardous Waste and Real Estate Transactions.

Hazardous Waste Contamination of Water Resources: (Superfund Clean-up Policy and the Seymour Recycling Case)

... Onity SPECIAL HANDLING INSTRUCTIONS COMMENTS If an AQ commodity is sprited on a waterway or adjoining land must be promptly reported to the Federal government at 1-800- free or 202-426-26.75 ( toll call if other DOT Hazardous Materials ...

OSHA and Hazardous Waste Sites: Hearing Before a Subcommittee of the Committee on Government Operations, House of Representatives, Ninety-ninth Congress, First Session, March 27, 1985

... ANSI Z88.2 ( 1969 , 1980 ) require that only positive pressure demand self - contained breathing apparatus ( SCBAs ) be used . It is therefore the policy of E & E that employees responding to environmental emergency situations with ...

New Jersey Hazardous Waste Program Status Report: Status report

... DRUM REMOVAL PUBLIC MYERS PROPERTY / MAIN PUBLIC NASCOLITE / FENCING - SURF ... DRUM & SOIL REMVL PRIVATE PIJAK FARM PJP LANDFILL PJP LANDFILL PJP LANDFILL PIJAK ... RMV PUBLIC RENORA RENORA / MAIN PRIVATE RENORA RENORA / SURFACE REMOVAL ...

Guidance Document for Providing Alternative Water Supplies

... supply may not be required . This decision will be contingent upon the ability of the remaining supplies to meet the ... documents . The CRP is the planning document for managing the interaction between the community and the technical ...

Known Contaminated Sites in New Jersey

... PUBLIC WORKS HAWTHORNE BOROUGH HIGH SCHOOL HAWTHORNE CHEVROLET HAWTHORNE GULF SERVICE STATION HAWTHORNE MUNICIPAL WELLFIELD CONTAM HAWTHORNE REALTY HAYES BUS COMPANY HAYWARD POOL PRODUCTS INCORPORATED HAZLET TOWNSHIP MAINTENANCE YARD ...

Known Contaminated Sites in New Jersey

... LST " reports are electronically generated lists that are intended to be viewed and printed from a DOS prompt , using DOS browse and print commands . They are available in either printable or ASCII formats . The two formats are further ...

Notification of Hazardous Waste Activity

... column in the production of ( T ) epichlorohydrin . Heavy ends from the fractionation column in ethyl chloride production .... Heavy ends from the distillation of ethylene dichloride in ethylene dichloride ( T ) production . E EEEE EE ...

Superfund: Proceedings of the ... National Conference

... test plots . Within these test plots , sampling locations were identified ... MR15 $ 819 S820 MR6 6.5 2.35 64 MR7 9.2 1.96 79 MR8 42.4 1.43 97 MR9 22.1 ... MR15 39.8 6.22 84 SOUTH MR16 4.6 3.04 34 ROOM MR17 8.1 4.12 49 MR18 60.0 5.82 90 ...

An Examination of the Integrity of Five Hazardous Waste Disposal Sites in the Great Lakes Basin: A Report to the Virtual Elimination Task Force of the International Joint Commission

... Virtual Elimination Task Force. 132 . 133 . 134 . 135 . 136 . 137 . 138 . 139 ... CH2M Hill Engineering . Chicago , Illinois ; August 1987 . U.S. ... Office of Research and Development . " Dense Non Aqueous Phase Liquids : A Workshop ...

Hazardous Waste Control and Enforcement Act, H.R. 2867: Small quantity generators

... subtitle C of RCRA- the hazardous waste provisions - if they are managed at ... generator status , although in total , they produce only 1 percent of all ... auto repair shops , dry- cleaning plants , machinery manufacturers , and ...

This website uses cookies and collects data for optimal performance. Your continued use signifies agreement to our Privacy Policy.