category: cogeneration of electric power and heat

ASME COGEN TURBO Power

... 1994 , " Development of a 24 kw Gas Turbine- Driven Generator Set for Hybrid ... Performance , " ASME Paper 71 - GT - 67 . McDonald , C. F. , 1972 , " Gas ... Performance Enhancement Applications and Technology , " Proceedings of 1990 ...

Application for Certification, Moss Landing Power Plant: Monterey, California

... ASTM A105 - Standard Specification for Forgings , Carbon Steel for Piping Components ASTM A106 - Standard Specification for Seamless Carbon Steel Pipe for High Temperature Service ASTM A159 Standard Specification for EFW Steel Pipe ...

Combined-cycle Gas & Steam Turbine Power Plants

... steam generated in the LP evaporator and super- heater ( 6 , 5 ) is available for the dual - admission steam turbine ... Pegging Steam Pump NATURAL GAS 2 15 16 170 18 10 G 11 12 13 140 Figure 4-21 Flow Diagram of a Dual Pressure Cycle ...

Commission Decision: Application for Certification for Midway-Sunset Cogeneration Company's Midway-Sunset Cogeneration Project

... ANSI C80.5 UL 797 , ANSI C80.3 UL 514 , ANSI C80.4 UL 886 u ! UL 360 NEMA TC6 NEMA TC9 F 691 NEMA TC2 , UL 514 ANSI / L C37.30 ANSI C37.32 ANSI C37.33 ANSI / 11 , C37.34 ANSI C37.5 Distribution Low Voltage Cartridge Fuses , 600V or less ...

Presiding Member's Report, Application for Certification for Sun Cogeneration and Southern Sierra Energy Companies' Midway-Sunset Gogeneration Project

... ASTM C39-84 Compressive Strength of Cylindrical Concrete ASTM C42-84 Method of Obtaining and Testing Drilled Cores and Sawed Beams of Concrete ASTM CL43-78 Test Method for Slump of Portland Cement Concrete ASTM C156-80 Test Method ...

The Qualifying Facilities Report

... JOHN KOYLE 12-12-82 N N NO SP HYD 1050 GOODING CTY ID DOCKET DESC : ROSEMARY PERKINS FLANIGIN 07-22-83 10-20-83 04-84 N C NO C ST C 12000 SHERIDAN WY DOCKET DESC : COGEN POTLATCH CORPORATION 1 01-14-83 E N UNC с ST WWA 6500 LEWISTOWN ID ...

Proceedings of the 1989 Industrial Power Conference

... tank integrity analysis is conducted during a hydrotest , i.e. , when the tank is initially filled with water to inspect for leakage . In the past , the American Petroleum Institute ( A.P.I. ) inspection procedure involved filling the tank ...

Commission Decision: Application for Certification for Kerr McGee Chemical Corporation's Argus Cogeneration Expansion Project

... 612 - Centrifugal Pumps - Lube Oil , Seal Oil and Control Systems for Package Units - Gear Units - Couplings ... ASTM Section VIII - API 660 - TEMA - ASME Section I - ASME Section II - ASME Section I , II , - ANSI B31.1 · ASTM C - 64 ASTM ...

Cogeneration Planner's Handbook

... worksheet as Item A. The second set of questions deals with historic utility ... load using an 80 % efficient boiler , is used to estimate the size of a ... electrical output is divided by the number of operating hours ( see Table 9-5 ) ...

Public Utility Regulatory Act: Hearings Before the Subcommittee on Energy and Power of the Committee on Energy and Commerce, House of Representatives, One Hundredth Congress, First Session, September 10, 22, and 23, 1987

... retail relay . In conclusion , FERC should nurture State programs and their evolution , much like the original PURPA law and regulations have already done . States can and do experiment with new and different ideas and are the ideal ...

Combined Heat and Power Market Assessment: Final Consultant Report

... NAICS code . This algorithm , originally developed for a previous national market assessment of distributed energy potential , was modified to reflect California - specific conditions based on information contained in the California ...

Commercial Status: Electrical Generation and Nongeneration Technologies: Staff Report

... cycling systems for residential central air conditioners and electric water heaters -- 8 percent of all such ... SCE and PG & E in several demonstrations of commercial air conditioner cycling . In approximately two years , there should ...

Revised Presiding Member's Proposed Decision: Los Esteros Critical Energy Facility II, Phase 2 : Application for Certification (03-AFC-2), Santa Clara County

... ups by GR Baxter 2/11/04 For AFC data adequaay request . CALIFORNIA ENERGY ... HRSC STACK STEAM TURBINE COOLING TOWER ( 6 CELL ) ( NEW ) FUEL OAS ... ID BOLER FEED WATER PUSPS ( NEW ) RAW WATER STORAGE TANK WATER WASH DRAIN TANKS GO ...

BP Cherry Point Cogeneration Project: Environmental Impact Statement

... RR3 rural residential 3 units / acre FIGURE 3.10-1 ZONING HII heavy impact industrial STC small town commercial Ul ... Graphics Server / Graphics / Billable / BP Cherry Paint / ES / Fig 3.10-1Zoning 8.103 OF GEORGIA RC NC UR4 URM6 GC GC ...

This website uses cookies and collects data for optimal performance. Your continued use signifies agreement to our Privacy Policy.