author: david kent ballast

PPI Interior Design Reference Manual: Everything You Need to Know to Pass the NCIDQ Exam eText - 1 Year

... show which existing construction is to remain and which is to be removed. A separate construction plan ... electrical outlets, telephone outlets, and other signal systems, like the ... does not produce a power plan, then the power plan drawn by ...

PPI NCIDQ Interior Design Reference Manual, 7th Edition—Includes Complete Coverage of Content Areas for All Three Sections of the NCIDQ Exam

... open-web steel joist system (a) beam-and-girder system ductwork or installing large recessed light fixtures should be reviewed before final decisions are made about the reflected ceiling plan. In an open-web steel joist system, joists ...

Handbook of Construction Tolerances

... ASTM C1048, Standard Specification for Heat-Treated Flat Glass–Kind HS, Kind FT Coated and Uncoated Glass (West Conshohocken, PA: American Society for Testing and Materials, 2004). GANA Glazing Manual (Topeka, KS: Glass Association of ...

Interior Detailing: Concept to Construction

... ASTM INTERNATIONAL: ASTM C1048 Specification for Heat Treated Flat Glass HARDWARE Hinges and Pivots AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI): ANSI A156.1 Butts and Hinges ANSI A156.7 Template Hinge Dimensions ANSI A156.17 Self ...

Architect's Handbook of Construction Detailing

David Kent Ballast. Figure 3-9 Open web steel joists 05 21 19 fascia as required steel decking or other structural deck as required open web steel joist L · 2 1/2 " ( 64 ) typ . · field weld joists to anchor plate Limitations of Use ...

PPI Interior Construction & Detailing for Designers & Architects eText - 1 Year

... wood can be harvested as a by-product. Palm wood flooring is available in 3⁄4 in × 3 in wide strips with tongue-and-groove edges like those of standard oak or maple flooring. It has a 1600 psi hardness on the Janka hardness scale and a ...

PPI ARE 5.0 Exam Review All Six Divisions, 2nd Edition eText - 3 Months, 6 Months, 1 Year

... Web Steel Joists web steel joist (fig) Fig. 21.23 Open-Web Steel Joist Fig. 41.4 Open-Web Steel Joist web steel joist system Sec. 11.1 Standard Structural Systems web steel joist, load table (tbl) Table 41.9 Standard Load Table for Open-Web ...

PPI NCIDQ Interior Design Reference Manual, Seventh Edition eText - 1 Year

... open-web steel joist system (a) beam-and-girder system ductwork or installing large recessed light fixtures should be reviewed before final decisions are made about the reflected ceiling plan. In an open-web steel joist system, joists ...

Architecture Exam Review: Nonstructural topics

... Architectural License Seminars . Mechanical / Plumbing / Electrical Systems . Los ... 2nd ed . Chicago : University of Chicago Press , 1984 . Egan , M. David ... Woodwork Institute . Architectural Woodwork Quality Standards , Guide ...

Architect's Handbook of Construction Detailing

... Architectural Woodwork Institute . Architectural Woodwork Quality Standards , Guide Specifications and Quality Certification Program , 5th ed . Arlington , VA : The Architectural Woodwork Institute , 1988 . Newman , Morton . Structural ...

Architecture Exam Review: Structural topics

... column . The ties must be arranged so that every corner and alternate ... tied col- umns . B. Spiral Columns Spiral columns have a continuous spiral ... column , but they may also be round . 6 " clear maximum without additional ties ( a ) ...

Interior Detailing: Concept to Construction

Interior Detailing: Includes 150 easy-to-understand details showing how to logically think through the design and development of an assembly so that it conforms to the designer's intent and meets the practical requirements of good ...

Interior Construction & Detailing for Designers and Architects

... ASTM C - 423 ASTM C - 635 ASTM C - 636 ASTM E - 580 Test Methods for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method Metal Suspension Systems for Acoustical Tile and Lay - in Panel Systems ...

Architecture Exam Review: Structural topics

... 15 = 383 foot - kips Looking in Table 10.5 , the lightest weight 12 - inch ... ksi . The ratio is 22/24 0.92 . = 0.92 × 406 = 372 foot - kips , which is less ... The allowable load per foot is 46.67 / 12 3.89 kips . C. Design for Shear ...

PPI ARE 5.0 Practice Questions All Six Divisions, 2nd Edition eText - 1 Year

... tables and chairs (not shown). Exit access corridors adjoin the north and east sides of the room. Using the information in the building code excerpt and partial occupant load table, select the drawing that shows the required door(s) in ...